ADJUSTMENTS

PNEUMATIC SYSTEM CASSETTE

A. VACUUM PUMP CASSETTE
PURPOSE:
The vacuum has to be in the correct range. If the vacuum is too low, a FILM might not be
picked up in the CASSETTE. If the vacuum is too high a FILM might not be separated from
the CASSETTE SCREEN.
1
.
Connect VACUUM GAUGE PN 29010170.
Connect the VACUUM GAUGE here
2
.
Loosen LOCKNUT at VACUUM PUMP.
VACUUM PUMP
CASSETTE
VACUUM SWITCH
FINE ADJUSTMENT
KODAK AG, Stuttgart
figure 4-85
SCREW
figure 4-86
4-83
3053-3
BRASS NUT
LOCK NUT