Checking the Detector Switches

[1]
Check that all film is removed from between
the ENTRANCE DETECTOR ROLLERS.
[2]
Connect the PORTABLE COMPUTER to the
15-PIN DIAGNOSTIC CONNECTOR on the
ELECTRICAL BOX.
See the User Instructions, Publication
Part No. 699614, for the operation of
the diagnostic procedures.
[3]
Enter the ''SPECIFIC TEST MODE'' of the
diagnostic program on the PORTABLE
COMPUTER.
ENTRANCE
DETECTOR
ROLLER
2B6845
NOTE
FILM STRIP
2.5 cm (1 in.)
Drive
Side
Feeding the Film Strip Between the Entrance Detector Rollers
[4]
Select the ''PROCESSOR SENSOR TEST''.
The ''PROCESSOR SENSOR TEST'' will
provide you with the status of the 2 film
DETECTOR SWITCHES.
[5]
Check that the message ''No film detected'' is
displayed on the PORTABLE COMPUTER.
[6]
Lift the top ENTRANCE DETECTOR
ROLLER, and insert the 2.5 cm (1 in.) FILM
STRIP between the ENTRANCE DETECTOR
ROLLERS on the drive side of the
PROCESSOR.
H104_0370DCA
H104_0370DC
6-21