Statistics Markers

After patterns are assigned to the X and O markers, statistical
information is available when markers are set to statistics. The logic
analyzer displays the following information:
Number of valid runs (runs where Pattern markers were placed on
specified patterns).
Minimum time between the X and O Pattern markers.
Maximum time between the X and O Pattern markers.
Average time between the X and O Pattern markers.
In a State analyzer, Statistics markers only become available when the
Count field is set to Time in the Trigger menu.
The markers are graphically accented in the display by dashed lines.
In addition, both markers are labeled at the bottom of the display in
the Display Location Reference Line.