Advertisement

Quick Links

User's Guide
Agilent 16441A R-Box
Agilent Part No. 16441-90000
Printed in Japan
January 2000
Edition 4

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 16441A R-Box

  • Page 1 User’s Guide Agilent 16441A R-Box Agilent Part No. 16441-90000 Printed in Japan January 2000 Edition 4...
  • Page 2: Legal Notice

    If Agilent Technologies receive notice of such defects during the warranty period, Agilent Technologies will, at its option, either repair or replace products which prove to be defective.
  • Page 3 To the extent allowed by local law, the remedies in this warranty statement are customer’s sole and exclusive remedies. Expect as indicated above, in no event will Agilent Technologies or its suppliers be liable for loss of date or for direct, special, incidental, consequential (including lost profit or date), or other damage, whether based in contract, tort, or otherwise.
  • Page 4 Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to a Agilent Technologies Sales and Service Office for services and repair to ensure that safety features are maintained.
  • Page 5 • Safety Symbols The general definitions of safety symbols used on equipment or in manuals are listed below. Instruction manual symbol: the product will be marked with this symbol when it is necessary for the user to refer to the instruction manual in order to protect against damage to the instrument.
  • Page 6: Printing History

    • Herstellerbescheinigung GEÄUSCHEMISSION Lpa < 70 dB am Arbeitsplatz normaler Betrieb nach DIN 45635 T. 19 • Manufacturer’s Declaration ACOUSTIC NOISE EMISSION Lpa < 70dB operator position normal operation per ISO 7779 Printing History Edition 1: February 1994 Edition 2: April 1995 Edition 3: August 1997...
  • Page 7 User's Guide Agilent 16441A User’s Guide, Edition 4...
  • Page 8 User's Guide Agilent 16441A R-Box is one of the accessories available for Agilent 4155/4156 Semiconductor Parameter Analyzers. The R-Box is used to add a series resistance (0 W, 10 kW, 100 kW, or 1 MW) between the 4155/4156’s SMU output and your test device (DUT), and is useful for the following measurements: •...
  • Page 9 When the 16441A arrives at your site, make sure that nothing is missing or damaged. Unpack the carton, then check the contents. See figure and table shown above. If anything is missing or damaged, contact your nearest Agilent Technologies sales office. Agilent 16441A User’s Guide, Edition 4...
  • Page 10: Operation

    User's Guide Operation Operation The R-Box adds a series resistance between the 4155/4156 Semiconductor Parameter Analyzer and DUT. Available resistance values are 0 W, 10 kW, 100 kW, and 1 MW. There is two channels (CH1 and CH2) to connect SMUs. Switching of resistance is controlled by the 4155/4156.
  • Page 11 User's Guide Operation Additional measurement channel is used for the automatic measurement of the current through R-Box. This is necessary to perform compensation calculation. Selecting Resistance Value Install the R-Box as shown in “Installation”, and turn on the 4155/4156. Then do following: 1.
  • Page 12: Circuit Diagram

    User's Guide Operation Circuit Diagram The simplified circuit diagram of the R-Box is shown below. The table below shows the internal relay positions for each resistance setting. Relay Switches Settings 10 kW 100 kW 1 MW Agilent 16441A User’s Guide, Edition 4...
  • Page 13: Installation

    User's Guide Installation Installation This section describes how to attach the R-Box to Agilent 16442A test fixture or to a shielding box, and how to connect it to the 4155/4156. To Attach the R-Box to Test Fixture You can attach your R-Box to Agilent 16442A test fixture as shown below. You need a standard screwdriver.
  • Page 14 User's Guide Installation The following steps apply when using the 16440A selector: 5. Place the selector on your workbench. Place the R-Box and the test fixture on top of the selector. 6. Position a plate on both sides. 7. Attach each plate using the three flathead screws supplied with the instrument.
  • Page 15 User's Guide Installation To Attach the R-Box to Shielding Box You can attach your R-Box to a shielding box. You need a standard screwdriver. The following figure shows the spacing of the 16441A screw holes. You need to prepare four screws and nuts to match the screw holes. Agilent 16441A User’s Guide, Edition 4...
  • Page 16 User's Guide Installation Attach the R-Box to the shielding box as shown below: 1. Attach an angle bracket to each side of the R-Box, using the screws supplied. 2. Place the R-Box on the side panel of the shielding box. 3.
  • Page 17 User's Guide Installation If you use the 16440A selector, attach the selector to the R-Box as shown below: Agilent 16441A User’s Guide, Edition 4...
  • Page 18 User's Guide Installation Connecting the R-Box to the 4155/4156 Before connecting the R-box to the 4155/4156 and 41501, turn off the instruments. 1. Connect the To R-Box terminal on the 4155/4156 rear panel to the Control terminal on the R-Box rear panel using a 3.0 m or 1.5 m control cable. 2.
  • Page 19 User's Guide Installation The following figure shows example connections with the 4156. The following figure shows example connections with the 4155. Agilent 16441A User’s Guide, Edition 4...
  • Page 20: Maintenance

    This section provides information for trained service personnel to repair the R-Box. When a replaceable part, which is shown with the Agilent part number in this section, needs to be replaced, order the parts from the nearest Agilent Technologies Sales and Service Office.
  • Page 21: Circuit Block Diagram

    User's Guide Maintenance Circuit Block Diagram Circuit Block Diagram is shown below: Control Circuit is shown below: Agilent 16441A User’s Guide, Edition 4...
  • Page 22: Performance Verification

    For the procedures to verify the performance of the R-Box by using the 4155/4156, refer to the 4155/4156 Service Manual. Test Equipments Digital Multi Meter Agilent Technologies 3458A or equivalent can force 20 V and 100 mA. Power Supply Connection Cables 04155-61650, 2ea 23 ±...
  • Page 23 User's Guide Maintenance Test Procedure 1. Apply dc voltage to the control circuit of the R-Box by the power supply as follows: +20 V 2. Connect the R-Box and DMM as follows: 3. Change the setting of the SW1 on the circuit board of the R-Box and verify the resistance value measured by the DMM as follows: CH1 Path Test: SW1 Setting...
  • Page 24 User's Guide Maintenance 4. Change the connection between the R-Box and DMM as follows: 5. Change the setting of the SW1 on the circuit board of the R-Box and measure the resistance value by the DMM to verify the resistor paths as follows: CH2 Path Test: SW1 Setting Test...
  • Page 25 User's Guide Maintenance 6. Change the connection between the R-Box and DMM as follows: 7. Change the setting of the SW1 on the circuit board of the R-Box and measure the resistance value by the DMM to verify the resistor paths as follows: Sense Path Test: SW1 Setting Test...
  • Page 26: Replaceable Parts

    User's Guide Maintenance Replaceable Parts When wiring or soldering, use low hydrochloric acid solder (Agilent part number: 8090-0433) to prevent the flux in the solder from spreading unnecessarily. When soldering, make sure the terminals do not make contact with each other. After soldering, make sure that there are no lint bridges so that leakage current is minimal.
  • Page 27 User's Guide Maintenance Reference Agilent Description Designation Part Number 0698-2036 Resistor 1MW 0.1 % .25 W 0699-3702 Resistor 2.525KW 0.02 % 0699-0208 Resistor 1W 5 % .25 W 0699-3702 Resistor 2.525KW 0.02 % 0699-3702 Resistor 2.525KW 0.02 % 0699-3702 Resistor 2.525KW 0.02 % 0698-2036 Resistor 1MW 0.1 % .25 W 0699-3702...
  • Page 28 User's Guide Maintenance Reference Agilent Description Designation Part Number 0757-0418 Resistor 619W 1 % .125 W 0757-0465 Resistor 100KW 1 % 0757-0465 Resistor 100KW 1 % 0757-0465 Resistor 100KW 1 % 0757-0465 Resistor 100KW 1 % 0757-0465 Resistor 100KW 1 % 0757-0465 Resistor 100KW 1 % 0698-3160...
  • Page 29 User's Guide Maintenance Reference Agilent Description Designation Part Number 8159-0005 Wire (Resistor 0W ) 8159-0005 Wire (Resistor 0W ) 8159-0005 Wire (Resistor 0W ) 8159-0005 Wire (Resistor 0W ) 8159-0005 Wire (Resistor 0W ) 8159-0005 Wire (Resistor 0W ) 1990-0967 LED Green 1990-0967 LED Green...
  • Page 30: Specifications

    • Function Agilent 16441A R-BOX adds a selectable series resistor to the SMU output. You can select the resistor from the setup page, and the voltage drop due to the series resistor is automatically calculated. There are the limitations on measurement with Agilent 4155/4156 Semiconductor Parameter Analyzers and R-Box: •...
  • Page 31 User's Guide Specifications • Voltage and current range • maximum voltage: 200 V maximum current: 1 A (when 0 W is selected) • • Accessories (furnished). See “Introduction” for details. • Option 001 • 1.5 m control cable (Agilent part number 04155-61610) •...
  • Page 32: Supplemental Information

    User's Guide Specifications Supplemental Information The following reference data is specified at 23 ± 5 °C and 50% relative humidity. less than 100 fA at 100 V Leakage current 0.3 W typical (when 0 W is selected) Residual resistance Output channel stray capacitance force to common 0.3 pF typical (at DC, without cable) force to guard...

This manual is also suitable for:

16441-90000