Statistics Markers

After patterns are assigned to the X and O markers, statistical
information is available when markers are set to Statistics. The logic
analyzer displays the following information:
Number of valid runs (runs where Pattern markers were able to be
placed on specified patterns).
Minimum time between the X and O Pattern markers.
Maximum time between the X and O Pattern markers.
Average time between the X and O Pattern markers.
In a State analyzer, Statistics markers only become available when the
Count field, in the Trigger menu, is set to Time.
The markers are graphically displayed by horizontal lines. In
addition, both markers are labeled at the left end of the marker line.