Agilent Technologies 1660A Series User Reference page 410

50/100-mhz state, 500-mhz timing logic analyzers
Table of Contents

Advertisement

Product Regulations
Safety
IEC 348:1978 / HD 401 S1:1981
UL 1244
CSA-C22.2 No. 231 (Series M-89)
EMC
This Product meets the requirement of the European Communities (EC)
EMC Directive 89/336/EEC.
Emissions EN55011/CISPR 11 (ISM, Group 1, Class A equipment)
Immunity
Sound Pressure
Less Than 60 dBA
Level
EN50082-1
IEC 555-2
IEC 555-3
IEC 801-2 (ESD) 8kV AD
IEC 801-3 (Rad.) 3 V/m
IEC 801-4 (EFT) 0.5 kV, 1kV
Performance Codes:
1 Pass - Normal operation, no effect.
2 Pass - Temporary degradation, self recoverable.
3 Pass - Temporary degradation, operator intervention required.
4 Fail - Not recoverable, component damage.
Notes:
1 TTL logic threshold, all cables disconnected
2 The GPIB and RS232 cables were temporarily attached for the
appropriate EFT test.
Code
Notes
1
1
1
1
2
1
1
1
1
1,2