Glitch/Edge Width
Glitch/Edge Recovery Time Sample period 2-8 ns: 28 ns.
Sample period > 8 ns: 20 ns + sample period.
Greater than Duration (timing only) Sample period 2-8 ns: 8 ns to
8.389 ms. Accuracy is -2 ns to +10ns.
Sample period > 8 ns: (1 to 2^20) x sample period. Accuracy is -2 ns to
+sample period + 2 ns +/- 0.01%.
Less than Duration (timing only) Sample period 2-8 ns: 16 ns to
8.389 ms. Accuracy is +2 ns to -10 ns.
Sample period > 8 ns: (1 to 2^20) x sample period. Accuracy is 2 ns to
-sample period - 2 ns +/- 0.01%.
Qualifier A user-specified term that can be any state, no state, any
recognizer, (patterns ranges or glitch/edges), any timer, or the logical
combination (NOT, AND, NAND, OR, NOR, XOR, NXOR) of the
recognizers and timers.
Branching Each sequence level has a branching qualifier. When
satisfied, the analyzer will branch to the sequence level specified.
Occurrence Counters Sequence qualifier may be specified to occur up
to 1,048,575 times before advancing to the next level. Each sequence
level has its own counter.
Maximum Occurrence Count 1,048,575
Storage Qualification (state only) Each sequence level has a
storage qualifier that specifies the states that are to be stored.
Maximum Sequencer Speed 125 MHz
State Sequence Levels 12
Timing Sequence Levels 10
Specifications and Characteristics
Specifications and Characteristics
1660A 136
1661A 102
1662A 68
1663A 34
1664A 34
19–9