Service Call 600-672 (Controller); Sc632 To Sc653, Sc670 To Sc672 - Ricoh Pro C7200S Troubleshooting Manual

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

Service Call 600-672 (Controller)

SC632 to SC653, SC670 to SC672

SC No.
Level
SC641-00
D
SC No.
Level
SC672-
D
Controller start up error
10
After the machine was powered on, communication between the controller and
the operation panel was not established.
SC No.
Level
SC672-
D
Controller start up error
11
After the machine was powered on, communication between the controller and the
operation panel was not established, or communication with controller was
interrupted after a normal startup.
Error Name/Error Condition/Major Cause/Solution
Communication error between BCU and Controller board.
Controller board does not respond after BCU tries to communicate three times.
Controller board software error
Connect error between BCU and Controller board
Engine board software error
Check connections between Controller board and BCU.
Turn the main switch off and on.
Error Name/Error Condition/Major Cause/Solution
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Turn the main power off/on.
Check the connection of the controller board.
Replace the controller board.
Check the control panel harness.
Error Name/Error Condition/Major Cause/Solution
Controller stalled
Board installed incorrectly
Controller board defective
Operation panel connector loose, broken, or defective
Controller late
Turn the main power off/on.
Check the connection of the controller board.
1.SC Codes
119

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents