1.SC Codes
SC No.
Level
4.
SC No.
Level
SC512-
D
Rotary gate HP error
00
SC No.
Level
SC514-00
D
SC No.
Level
SC515-00
D
94
Error Name/Error Condition/Major Cause/Solution
Pressure Release HP Sensor
Vertical Transport Exit Contact Motor
Replace the Main Control Board of the LCIT.
Error Name/Error Condition/Major Cause/Solution
Failed to detect "home position ON" during 2 rotations of the rotary gate after
the rotary gate stepping motor started to rotate.
Failed to detect "home position OFF" during 2 rotations of the gate after
"home position ON" was detected
("2 rotations of the gate" is equal to 877 msec.)
Rotary gate stepping motor disconnected or defective
HP sensor disconnected or defective
Malfunction due to overload
Malfunction due to an error in the motor driver
Actuator deformed, damaged, or improperly installed
Cycle the main power switch off/on.
Check or replace the corresponding motor, sensor, or harness.
Check the drive part for the load, foreign matters, etc.
Check the Actuator.
Check or replace the PCB.
Error Name/Error Condition/Major Cause/Solution
Registration Shift Position Error
Home position on/off was not detected within the time limit.
Shift Unit Motor connector disconnected and defective
Shift Unit HP Sensor connector disconnected and defective
Defective operation due to overload
Defective operation due to the motor driver defective
Shift Unit HP Sensor shield deformed/broken/incorrectly attached
Error Name/Error Condition/Major Cause/Solution
CIS cleaning fan Error
During fan lock detection
Overload
Fan stopped by foreign object