Ricoh Pro C7200S Troubleshooting Manual page 158

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

1.SC Codes
SC No.
Level
SC No.
Level
SC720-12
D
SC No.
Level
SC720-13
D
SC No.
Level
SC720-
B
15
154
Error Name/Error Condition/Major Cause/Solution
Reconnect the connectors.
Replace the harnesses.
Replace the Main Board.
Error Name/Error Condition/Major Cause/Solution
Transport Motor Error 3 (Downstream From Punch Unit)
Same as SC720-10
Same as SC720-10
Replace the Junction Gate Transport Motor.
Reconnect the connectors.
Replace the harnesses.
Replace the Main Board.
Error Name/Error Condition/Major Cause/Solution
Transport Motor Error 4 (registration)
Same as SC720-10
Same as SC720-10
Replace the Registration Motor.
Reconnect the connectors.
Replace the harnesses.
Replace the Main Board.
Error Name/Error Condition/Major Cause/Solution
Transport Motor Error 6 (Pre-stack)
DC motor drive software detected an error (this SC issues immediately at 1
occurrence).
Motor defective
Connecter disconnected
Overload
Encoder defective
Replace the Pre-stack Motor
Reconnect the connectors.
Replace the harnesses.
Replace the Main Board.
st