Ricoh Pro C7200S Troubleshooting Manual page 669

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

3. Debug Cable
Save Timing
A log is continuously saved when
executing log capture at "Teraterm".
Capturing a log in special cases. Through the Debug Cable only, it is possible to capture
special logs (fixing temperature log, etc.) by entering commands.
Procedures for Capturing the Engine Debug Log via the Capturing Log Function
See the "Capturing the Debug Logs", Chapter 5 of Field Service Manual.
Procedures for Capturing the Engine Debug Log via the Service Slot Board (SDCU)
1.
Turn the main power switch OFF.
2.
Insert the SD card into the Service Slot Board (SDCU).
3.
Turn the main power switch ON.
4.
Enter the SP mode
5.
In the following SP, check that the state of the Service Slot Board (SDCU) is "1 (normal)".
SP5-901-001 (Engine Log SD Card Slave)
SP5-901-002 (Engine Log SD Card Master)
0: SDCU not connected
1: Normal
2: SD card not inserted
3: SD card error (card not recognized or access error)
4: Write-protected
5: Disk full
If the state is "1", log capture starts automatically when the board (SDCU) is installed and the SD
card is inserted (step 3).
6.
Execute the job or operation for which the error occurred.
7.
Turn the main power switch OFF.
8.
Remove the SD card.
9.
Send all files saved to the SD card to your supervisor.
Information equivalent to when entering the "log" command to capture the engine log via the
Debug Cable (described below) is automatically saved to the SD card.
Maximum Capture
Period
Depends on HDD
space at PC
12.Advanced Instructions
Use
Capturing a log when time is needed
to obtain the Service Slot Board.
Generally, we recommend using the
Service Slot Board to capture a log.
665

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents