SC756-
B
Ring Binder: 50/100 clamp adjustment error
44
SC No.
Level
SC756-
B
Ring Binder: Timing sensor interval error
45
At initialization or ring binding, the ON or OFF time of the timing sensor exceeded
358
Error Name/Error Condition/Major Cause/Solution
component at the home position within the prescribed time (400 ms). The first
occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home
position within the prescribed time (400 ms). The first occurrence triggers a
jam, the second an SC code.
Shutter motor (M608) defective
Motor overloaded
Connector loose, broken, defective
Shutter HP sensor 1 (S605) defective
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution
When moving to the home position, the sensor could not detect the
component at the home position within the prescribed time (400 ms). The first
occurrence triggers a jam, the second an SC code.
The sensor failed to detect that the component had moved out of the home
position within the prescribed time (400 ms). The first occurrence triggers a
jam, the second an SC code.
50/100 clamp adjustment motor (M702) defective
Connector loose, broken, defective
Motor overload
Ring switch HP sensor (S706) defective
Ring switch timing sensor (S707) defective
Replace the motor
Replace the sensor
Replace the connector
Reconnect the connector
Replace the board
Error Name/Error Condition/Major Cause/Solution