6.
At [Setup] > [Terminal], open the Terminal Setup screen and specify the following settings.
Terminal Size : under (80x25)
New Line: Transmit CR+LF
Local echo: Check box on
7.
At [Setup] > [Serial Port], open the Serial port setup screen and specify the following settings.
Port: COM x
(x : check COM number with Device Manager of PC)
Baud rate : 57600
Date: 8 bit
8.
At [File] > [Log], enter the file name and click "Open."
9.
Turn on the machine power switch. Enter "ver" in the "Teraterm" window and check for any
connection problems (Is a value returned? Is there a mistake for either master or slave?).
12.Advanced Instructions
Kanji (receive): SJIS
Kanji (receive): SJIS
Stop: 1 bit
Parity: none
Flow control : none
Transmit delay: 10 msec/char
667