Ricoh Pro C7200S Troubleshooting Manual page 127

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

SC No.
Level
SC605-00
D
SC No.
Level
SC618-
D
Buffer Pass Unit: CTB_+24V_Power Supply Error
01
Detected that the +24V power supply is off for the PCB: CTB of the Buffer Pass
Unit.
SC No.
Level
SC618-
D
Buffer Pass Unit : CTB_+24VINT_Power Supply Error
02
Detected that the +24VINT power supply is off for the PCB: CTB of the Buffer
Pass Unit.
Error Name/Error Condition/Major Cause/Solution
IOB FPGA startup error
Startup of Kamui2 (FPGA) is detected when the power was turned ON.
Harness between BCU and IOB disconnected
IOB error
1.
Cycle the main power switch off/on.
2.
Reconnect the harness between BCU and IOB.
3.
Replace the IOB.
Error Name/Error Condition/Major Cause/Solution
Error for PSU of Buffer Pass Unit
Connector disconnected
Harness grounding fault/disconnected
24V load (motor/fan) layer shorted
Error for Controller Board of Buffer Pass Unit
Fuse tripped (PSU, board)
Replace the PSU of Buffer Pass Unit
Reconnect the connectors.
Replace the harnesses.
Replace the motor/fan.
Replace the Controller Board of Buffer Pass Unit
Error Name/Error Condition/Major Cause/Solution
Error for PSU of Buffer Pass Unit
Connector disconnected
Harness grounding fault/disconnected
24V load (motor/fan) layer shorted
Error for Controller Board of Buffer Pass Unit
Fuse tripped (PSU board)
Board relay malfunction
Replace the PSU of Buffer Pass Unit
1.SC Codes
123