Level
even after the SG motor had operated for 1500 ms.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC754-
B
Perfect Binder: Sub grip close position lag error
52
At the start of the sub grip open operation, the SG close sensor did not go OFF,
even after the SG motor had operated for 500 ms.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC754-
B
Perfect Binder: Main grip HP sensor late error
53
Error Name/Error Condition/Major Cause/Solution
SG motor defective
SG close sensor defective
Harness connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the SG motor.
Replace the SG close sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
SG motor defective
SG close sensor defective
Harness connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the SG motor.
Replace the SG close sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
During main grip lift, the MG HP sensor did not go ON, even though the main
grip lift motor had operated for 6185 ms.
MG HP sensor did not go OFF when the main grip moved from up position to
down position.