1.SC Codes
SC No.
Level
SC586-33
D
SC586-40
D
SC586-41
D
SC No.
Level
SC587-
C
Main Unit Temperature Sensor Error
00
When errors are detected 3 times consecutively during 1-minute periods, it is
judged that an error has occurred and SC is issued.
SC No.
Level
SC589-
D
Toner Bottle Motor Error (Driver Error Detection):K
01
114
Error Name/Error Condition/Major Cause/Solution
Invert/Exit Motor
Decurl Motor
Decurler Paper Transport Motor
Detection period: 100 ms
SC if error detected 2 times consecutively
Driver overheating protection
Stepper Motor harness broken.
Stepper Motor shorted.
Harness disconnected.
Reconnect the connectors.
Replace the Stepper Motor.
Replace the harnesses.
Replace the PCB.
Replace the following boards.
-10 to 15: PFB
-20 to 25: DRB
-30 to 33: TDCU
-40, -41: DDRB
Error Name/Error Condition/Major Cause/Solution
-10 degrees or lower is detected for the measurement temperature of the
main unit temperature sensor.
80 degrees or higher is detected for the measurement temperature of the
main unit temperature sensor.
Connector disconnected or broken
Thermistor defective.
Connector disconnected or broken
Reconnect the connector.
Sensor defective
Replace the sensor.
Error Name/Error Condition/Major Cause/Solution