1.SC Codes
SC No.
Level
SC753-
B
39
SC No.
Level
SC753-
B
Electrical short in the gluing unit
40
A temperature of less than 5 degrees was detected for 1 sec. or more than 10 sec.
after power on.) However, if the thermistor detected less than 100 degrees after
measuring temperature at start up, temperature is checked again after 50 sec.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC753-
B
Perfect Binder: Glue heater startup error 1
41
Glue temperature thermistor did not detect a temperature of 140 degrees within
200 sec. after it detected a temperature over 50 degrees.
After the repairs, cancel the low performance mode, and then turn the power
296
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Glue heater error
The glue heater thermistor registered more that 200 degrees for more than 1
sec.
Glue temperature thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Glue temperature thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
Error Name/Error Condition/Major Cause/Solution
Glue temperature thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.