SC No.
Level
SC754-
B
Perfect Binder: Sub grip size HP sensor late error
47
When the sub grip unit opened horizontally, the size move HP sensor did not go
ON, even after the size move motor had operated for 726 ms, or operated long
enough for 108.75 mm of movement.
After the sub grip unit moved to the horizontal release position, the sub grip size
HP sensor was already OFF.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC754-
B
Perfect Binder: Sub grip size HP sensor lag error
48
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Sub grip size motor defective
Sub grip size HP sensor defective
Harness connector, loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the sub grip size motor.
Replace the sub grip size HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
When the sub grip unit closed horizontally, the size move HP sensor did not
go OFF, even after the size move motor had operated for 500 ms, or operated
long enough for 108.75 mm of movement.
After the sub grip unit moved from the horizontal close position to the open
position, the size shift HP sensor was already ON.
Sub grip size motor defective
Sub grip size HP sensor defective
Harness connector, loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the sub grip size motor.
Replace the sub grip size HP sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.