SC750-32
D
SC No.
Level
SC750-33
D
SC No.
Level
SC750-34
D
SC No.
Level
SC750-
D
Perfect Binder: Glue supply fan (high) lock error
35
Glue supply (high) fan failed to generate a lock signal within 12 sec., and signal
could be detected even after a re-try.
200
Error Name/Error Condition/Major Cause/Solution
Replace the motor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature fan 2 (rear) lock error
See SC750-31
Rear signature fan 2 overloaded, defective
Slave Control Board defective
Reconnect the connector.
Replace the rear signature fan 2.
Replace the slave board.
Replace the motor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature fan 1 (front) lock error
See SC750-31
Front signature fan 1 overloaded, defective
Slave Control Board defective
Reconnect the connector.
Replace the front signature fan 1.
Replace the slave board.
Replace the motor harness.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Signature fan 1 (rear) lock error
See SC750-31
Rear signature fan 1 overloaded, defective
Slave Control Board defective
Reconnect the connector.
Replace the rear signature fan 1.
Replace the slave board.
Replace the motor harness.
Error Name/Error Condition/Major Cause/Solution
Glue supply fan (high) overloaded, defective