SC No.
Level
SC No.
Level
SC752-74 D
Perfect Binder: Cover interposer tray EEPROM write error
When data were written to EEPROM, the write data and read data did not match.
SC No.
Level
SC752-
D
Perfect Binder: Drive switch motor error (down to up)
75
The rack where the drive gear is mounted did not retract from the drive switch
sensor after the drive switch motor operated for 3 s.
SC No.
Level
SC752-
D
Perfect Binder: Drive switch motor error (up to down) error
76
The rack where the drive gear is mounted was late arriving at the drive switch
sensor after the drive switch motor operated for 3 s.
Error Name/Error Condition/Major Cause/Solution
Replace the EEPROM on the inserter control board.
Replace the inserter control board.
Error Name/Error Condition/Major Cause/Solution
EEPROM defective
EEPROM not installed, not installed correctly
Replace the EEPROM on the inserter control board.
Replace the inserter control board.
Error Name/Error Condition/Major Cause/Solution
Drive switch motor defective
Drive switch sensor defective
Connector loose, broken, defective
Reconnect the connector.
Replace the drive switch motor.
Replace the drive switch sensor.
Replace the inserter control board.
Replace the motor harness.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Drive switch motor defective
Drive switch sensor defective
Connector loose, broken, defective
Reconnect the connector.
Replace the drive switch motor.
Replace the drive switch sensor.
Replace the inserter control board.
Replace the motor harness.
1.SC Codes