When a type D occurs, automatic reboot is done or the machine display asks the customer if it can
reboot. However, when the SC occurs twice in a short time, the machine sends a report to the
@Remote server without rebooting. This is because just rebooting may not be a good solution if an SC
occurs twice.
When an automatic reboot is performed, a confirmation screen is displayed after reboot. The
confirmation screen can be cancelled by pressing the [OK] key (display is not cancelled only when the
main power switch is switched OFF to ON).
Screen display during reboot
Status display on the current screen
Post-processing ...... Post-processing during printing, etc.
Automatic reboot .... After operation end
Post-processing
Until automatic reboot
Reset key (Reboot key)
Key to perform reboot
# Cancel key is not displayed.
Turn ON spanner LED (same as when an SC is generated).
Operation during SC reboot
Timing of SC reboot
When @Remote is enabled, and when a NRS alarm*1 is not generated, the corresponding SC is
the object of an automatic reboot.
*1 NRS alarm: Issued when an ordinary SC (type D) is generated twice while the total counter
counts 10 times.
Time to automatic reboot
Reboot is performed 30 seconds after an engine reboot is possible, after the end of post-
processing during printing, etc.
At that time, a reboot is performed even if the MFP is operating. The engine does not start process
control when a reboot is possible.
Automatic reboot
See the flowchart below.
1.SC Codes
9