Ricoh Pro C7200S Troubleshooting Manual page 119

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

SC No.
Level
SC589-
D
Toner Bottle Motor Error (Driver Error Detection):C
02
SC589-
D
Toner Bottle Motor Error (Driver Error Detection):M
03
SC589-
D
Toner Bottle Motor Error (Driver Error Detection):Y
04
The driver error detection signal for the Toner Bottle Cap Motor and Toner Bottle
Motor errors is monitored at 100ms intervals. When errors are detected 3 times
consecutively, it is judged that an error has occurred and SC is issued. It is not
possible to differentiate between Toner Bottle Cap Motor and Toner Bottle Motor
errors.
SC No.
Level
SC590-
D
Exit Motor Error
00
1000ms after starting the motor, "Lock Signal: Low" was not detected 10 times
consecutively during the time until the motor stop signal is received.
SC No.
Level
SC593-00
D
Error Name/Error Condition/Major Cause/Solution
175 degrees (typical) or higher
Specified current is 4us (typical) or higher
When an error is detected at 175 degrees (typical) or higher: automatic restart
at 150 degrees (typical) or lower
When an error is detected at specified current of 4us (typical) or higher: restart
by switching 24V or 5V OFF/ON
Error Name/Error Condition/Major Cause/Solution
Motor connector disconnected
Abnormal increase in the Exit Roller torque (overload due to the bearing lock,
etc.)
Motor driver malfunctioning
Exit Motor malfunctioning
Reconnect the motor connector
Eliminate the cause of overload in the exit unit.
Replace the motor driver.
Replace the Exit Motor.
Error Name/Error Condition/Major Cause/Solution
Decurler Over Limit
Decurler Limit Sensor is detected as on.
HP misdetection
1.SC Codes
115