Ricoh Pro C7200S Troubleshooting Manual page 145

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

SC No.
Level
SC No.
Level
SC685-04
D
SC No.
Level
SC685-05
D
SC No.
Level
SC685-07
D
Error Name/Error Condition/Major Cause/Solution
5.
Replace the PFB.
6.
Replace the BCU
7.
Replace IOB.
8.
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
DC Power Supply Voltage Error
When an error is detected for the 5V power supply to the Right Drawer Unit
1.
PSU overcurrent detected (grounding fault caused by harness or motor)
2.
PSU4 defective
3.
FU3/FU5 on PSU4 melted
4.
Connecter disconnected
5.
PFB malfunction
6.
BCU malfunction
7.
IOB malfunction
8.
Harness broken
1.
Replace the part where grounding fault occurred.
2.
Replace the PSU4.
3.
Replace the FU3 / FU5 on PSU4.
4.
Set the connector again.
5.
Replace the PFB.
6.
Replace the BCU
7.
Replace IOB.
8.
Replace the harness.
Error Name/Error Condition/Major Cause/Solution
DC Power Supply Voltage Error
When an error is detected for the 5V power supply to the Right Drawer Unit
1.
IOB load harness grounding fault or part malfunction
2.
IOB malfunction
1.
Replace the part with grounding fault or malfunction
2.
Replace IOB.
Error Name/Error Condition/Major Cause/Solution
DC Power Supply Voltage Error
When an error is detected for the 5V power supply to the Right Drawer Unit
1.
PSU overcurrent detected (grounding fault caused by harness or motor)
1.SC Codes