Ricoh Pro C7200S Troubleshooting Manual page 389

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

SC NO.
Level
00
An error occurred because the number of records exceeded the limit for images
managed in the service layer of the firmware.
This can occur if there are too many application screens open on the operation
panel.
Logging only.
SC No.
Level
SC997-
D
Application function selection error
00
The application selected by the operation panel key operated abnormally (No
response, abnormal ending).
Software bug (mainly the application)
SC No.
Level
SC998-
D
Application start error
00
Error Name/Error Condition/Major Cause/Solution
Error Name/Error Condition/Major Cause/Solution
Check the optional RAM, DIMM, boards required by the application program.
Check if the combination of downloaded programs are correct.
Error Name/Error Condition/Major Cause/Solution
No application was registered to system within a specified time after the main
power was turned on.
(No application starts/All applications have been terminated abnormally)
Application started but cannot be drawn now for some reason.
Software bug (mainly the application)
The optional RAM, DIMM, boards required by the application program. Are
not installed correctly.
Turn the main power off/on.
Check the optional RAM, DIMM, boards
Check the combination of programs
Replace the controller board.
1.SC Codes