SC No.
Level
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC753-
B
Perfect Binder: Cover horizontal registration sensor (S) adjustment high value
62
error
The cover horizontal registration sensor (S) A/D input value was lower than 3.2 to
3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after
cover registration sensor (S) D/A output value output was higher than 3.7V.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC753-
B
Perfect Binder: Cover horizontal registration sensor (L) adjustment high value error
63
The cover horizontal registration sensor (L) A/D input value was lower than 3.2 to
3.54V, and the A/D input value did not go higher than 3.2 to 3.54V, even after
cover horizontal registration sensor (L) D/A output value output was higher than
3.7V.
After the repairs, cancel the low performance mode, and then turn the power
Error Name/Error Condition/Major Cause/Solution
Replace the master control board.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Cover horizontal registration sensor (S) connector loose, broken, defective
Sensor defective
Slave control board defective
Reconnect the connector.
Clean the sensor.
Replace the cover horizontal registration sensor (S).
Replace the slave control board.
Replace the sensor harness.
Error Name/Error Condition/Major Cause/Solution
Cover horizontal registration sensor (L) connector loose, broken, defective
Sensor defective
Slave control board defective
Reconnect the connector.
Clean the sensor.
Replace the cover horizontal registration sensor (L)
Replace the slave control board.
Replace the sensor harness.
1.SC Codes
305