Ricoh Pro C7200S Troubleshooting Manual page 302

Hide thumbs Also See for Pro C7200S:
Table of Contents

Advertisement

1.SC Codes
SC No.
Level
SC No.
Level
SC753-
B
Perfect Binder: Glue level thermistor error 1
45
After glue warm-up completed, the glue level thermistor detected a temperature of
over 170 degrees for more than10 sec.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC753-
B
Perfect Binder: Glue level thermistor error 2
46
After glue warm-up completed, the glue level thermistor detected a temperature
less than 100 degrees for more than10 sec.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
SC No.
Level
SC753-
B
Perfect Binder: Thermistor disconnect error
47
The glue abnormal temperature thermistor detected a temperature of less than 5
degrees for 1 sec., or more than 10 sec. after power on. However, if the thermistor
detected less than 100 degrees after measuring temperature at start up,
temperature is checked again after 50 sec.
298
Error Name/Error Condition/Major Cause/Solution
off/on.
Error Name/Error Condition/Major Cause/Solution
Glue level thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
Error Name/Error Condition/Major Cause/Solution
Glue level thermistor defective
Glue heater defective
Slave board defective
Reconnect the connector.
Replace the gluing unit.
Replace the slave board.
Error Name/Error Condition/Major Cause/Solution
Glue abnormal temperature thermistor defective
Glue heater defective
Slave board defective