Data setting method

Data setting method is used to set a point at which the workpiece is positioned by a manual feed such as JOG operation as an
OP.
When the machine OPR is performed using the data setting method, Deviation counter clear signal is output to the drive unit
and the current feed value and machine feed value are overwritten with the OP address.
Operation chart
Machine OPR start
(Positioning start signal)
[Y10, Y11, Y12, Y13]
OPR request flag
[
Status: b3]
Md.31
OPR complete flag
[
Md.31
Status: b4]
Deviation counter clear output
Md.26
Axis operation status
Md.20
Current feed value
Md.21
Machine feed value
Operation precautions
• The OPR parameter areas ([Pr.43] to [Pr.57]) other than [Pr.45] OP address and [Pr.55] Deviation counter clear signal
output time are not used for the data setting method. However, if a set value is outside the setting range and PLC READY
signal [Y0] is turned on, an error occurs and RD75 READY signal [X0] does not turn on. To avoid the occurrence of an error
when PLC READY signal [Y0] is turned on, Set values within the setting range (or initial values) for the unused OPR
parameter areas.
• When performing an OPR operation using Data setting method for a device for which the backlash compensation function
is used, perform the manual control beforehand. Otherwise the backlash compensation cannot be properly executed.
2 OPR CONTROL
56
2.2 Machine OPR
v
Manual feed such
as JOG operation
OFF
OFF
OFF
Standby
A value of the movement amount is stored.
Inconsistent
t
ON
ON
ON
Deviation counter clear signal
Pr.55
output time
OPR
Standby
OP address