Position (Abs) - Mitsubishi Electric MELFA FR CR800 Series User Manual

Industrial robots
Table of Contents

Advertisement

14.5.1. Position (ABS)

Data concerning the position of each axis motor can be monitored.
The following data can be monitored.
-
Position feedback
Current motor rotation position is displayed by the pulse value of the encoder.
-
Position in 1 rotation
Present single motor rotation position of the encoder is displayed.
(It is not displayed in the CR800/750/700 series controller. It is always 0.)
-
Fdt command
The amount of the change of the position command between the control cycles is shown.
(It is not displayed in the CR800/750/700 series controller. It is always 0.)
-
Position droop
The amount of deflection at the motor rotation position relative to the position command is shown.
-
Max. position droop
The maximum value of position droop after robot controller's power supply is turned on is displayed.
-
Position command
The command of the motor rotation position for the servo is displayed by the pulse value.
Click the [Reset] button to reset all Servo Monitors.
14-319