Admin: Lamp Menu

From the Admin: Lamp menu, installers can record minimum and maximum footlambert readings to define a
range from which other lamp readings are interpolated.
Enable to automatically
reduce lamp power to
its minimum.
To Set FootLamberts Calibration
1. Ensure the lamp is turned ON.
2. Click Min Power to set the lamp power to its lowest value for the installed lamp. NOTE: If enabled,
LiteLOC™ is disabled when Min Power is clicked to allow setting minimum power for the lamp. Once the
value is applied, LiteLOC™ returns to its original state.
3. Enter the FootLamberts measured for the minimum lamp power in the Min FL text box by entering the
value or using the up/down arrow buttons.
4. Click Apply to save the Min FL value. Once Apply is clicked, the Min Power button becomes
unchecked, and the Apply button becomes greyed-out. Lamp power returns to the lamp power that it was
before Min Power was clicked.
5. Click Max Power to set the lamp power to its highest value for the installed lamp. NOTE: If enabled,
LiteLOC™ is disabled when Max Power is clicked to allow setting maximum power for the lamp. Once the
value is applied, LiteLOC™ returns to its original state.
6. Enter the FootLamberts measured for the maximum lamp power in the Max FL text box by entering the
value or using the up/down arrow buttons.
7. Click Apply to save the Max FL value. Once Apply is clicked, the Max Power button becomes
unchecked and the Apply button becomes greyed-out. Lamp power returns to the lamp power it was
before Max Power was clicked.
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
Figure 3-40 Admin: Lamp Menu Options
Section 3: Operation
Enable to automati-
cally increase lamp
power to its maximum.
Apply values.
Return to previously
saved values.