Lens Vertical Offset Adjustment (LVO)
DESCRIPTION - Adjust lens offset to specific vertical position. Lens movement range -2050 to 2050.
Use command without subcode:
If ILS is on, motor will move to specified steps and save data to the active channel.
If ILS is off, motor will move to specified steps, do not save data to the active channel
Use LVO with Subcode CXXX (active channel):
If ILS is on, motor will move to specified steps and save data to the active channel.
If ILS is off, motor will not move, save data to the active channel.
Use LVO with Subcode CXXX (inactive channel):
Just save data to specified channel, no hardware movement.
SUBCODE
DESCRIPTION OF USE
BACN
Motor backlash in negative direction, read-only for ILS.
BACP
Motor backlash in positive direction, read-only for ILS.
CXXX
Moving lens mount to a specified horizontal position. Data range is -2050 to 2050.
RNGP
Motor moving range in positive direction, read-only for ILS.
RNGN
Motor moving range in negative direction, read-only for ILS.
EXAMPLES:
(LVD -1) Set negative direction
(LVO 500) Move lens to position 500 at vertical motor
(LVO+CXXX -500) Set lens to position of channel XXX to -500 at vertical motor
(LVO ?) Return current motor position
Measured Color (MCG)
DESCRIPTION - Select the Measured Color Gamut file. This file describes the native colorimetry for the projector as
installed and is required for accurate color processing in the cinema electronics. This control is per channel to allow for different
colorimetry for applications such as 3D.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101 - 164.
NONE
Select measured color gamut for the current channel.
RFSH
Set (1) to refresh files, 0 do nothing
TEMP
Select the measured color file as DLP active file, do not change channel settings.
EXAMPLES:
(MCG+C108 "Nominal") Use file "Nominal" on channel
(MCG+C108?) Get measured color file name on channel 108
(MCG?L) List all entries of measured color control
(MCG+TEMP "Nominal") Use file "Nominal" as DLP active file
(MCG+RFSH 1) Refresh TI file list
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
Appendix A: Serial API