Christie CP2000-ZX User Manual page 136

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

Appendix A: Serial API
Intelligent Light System Config (ILS)
DESCRIPTION - Enable/disable the Intelligent Lens System in specified channel.
SUBCODE
DESCRIPTION OF USE
ACLB
Enable/disable the Auto Lens Mount and Lens reset feature. Once ACLB is turned on, lens mount and lens
system will be reset automatically when system is powered on.
BACE
Backlash enable flag (0/1). The default value is 1 (enabled).
CALB
Calibrate travel range and backlash on specified motor. 1-Horizontal Offset, 2-Vertical Offset, 3-Zoom, 4-
Focus, 5-All above.
CSTS
Motor calibration status (0-100%)
RSET
Move motor to center flag, the move back to current position. 1-Horizontal Offset, 2-Vertical Offset, 3-
Zoom, 4-Focus, 5-All above
RSTS
Motor reset status (0-100%)
NONE
(1/0) Enable/Disable the Intelligent Lens System for each channel
EXAMPLES:
(ILS 1) Enable ILS, lens will be moved to the position in each channel
(ILS 0) Disable ILS, position data in each channel will not be used. Moving lens will not affect any channel setting
(ILS+CALB 5) Calibrate all axes of the lens
(ILS+RSTS 5) Reset all axes of the lens
(ILS+ACLB 1) Reset lens automatically when power on
Internal Test Pattern (ITP)
DESCRIPTION - List and select internal test patterns. This command also create the customized test pattern list from the
internal test patterns. The list of available test patterns is determined by what files are loaded on the TI cinema electronics.
SUBCODE
DESCRIPTION OF USE
FULL
Set(1)/Reset(0) full screen size
KEEP
When KEEP=1, don't disable test pattern when changing channels
NOCR
NOCR set non-correction test patterns for measured color, range is 0 to 6
NONE
Select test pattern from full list of defined test patterns
RFSH
Set (1) to refresh files, 0 do nothing
SETP
Select test pattern from user defined test pattern list
USER
EXAMPLES:
(ITP ?) Get current test pattern, 0 means no test pattern is used.
(ITP 4) or (ITP " ") Use number or string to set test pattern
(ITP+USER 4) or (ITP+USER " ") Use number of string to set test pattern from user's test pattern list.
(ITP+FULL 1) Use full screen size
(ITP+FULL 0) Use active channel screen file
(ITP+NOCR 1) Set non-correction test patterns for measured color you can use
(ITP+RFSH 1) Refresh TI file list
(ITP+STUP "DC2K Framing Green, DC2K Framing Red") Add these two test patterns to the user list
A-8
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)