Section 3: Operation
Status: Interrogator Menu
The password-protected Status: Interrogator menu enables the collection of advanced-level status
information that can assist in the diagnostics of projector components. Interrogator can be run in two modes:
Basic Mode which enables the collection of log files only or Enhanced Mode which creates log files plus
registered batch files. These files are then stored wherever you specify on your PC. Warning! Never run
Interrogator during a show as this could cause image disruption.
NOTES: 1) For Interrogator to successfully
retrieve these diagnostic files, the projector must
remain in its "failed" state (with incorrectly
displayed image on screen). 2) Always run
Interrogator first before power cycling the
projector, otherwise important diagnostic files will
be unusable. 3) It can take 5-10 minutes for
Interrogator to complete its function. 4) There is no
way of stopping Interrogator once a request to run
it is applied. 5) Interrogator is also accessible
through a separate login and password (different
from the service login). Contact Christie tech
support for assistance and password.
After you run Interrogator, you will be prompted to specify a location on your PC to save the Interrogator file.
Depending on your browser's security settings, the downloaded file may be blocked. See Figure 3-15. If you
click the "Click here for options" message, you will be given an option to approve downloading the file. As
soon as you do this, the page refreshes and you are forced to log in again where you will need to duplicate this
process. Instead of running Interrogator again, go to http://IP_address/backup/ (remember to include the
ending slash). Right-click a file that ends in .tar.enc or .tar.tar and select "Save Target As...". Select the
location on your computer where you would like to save this file.
3.4.5 Alarm Window
In addition to the status indicator in the main toolbar of any web
user interface window, a full-screen red alarm window appears if
one of the alarm conditions are encountered (Figure 3-16). This
window displays a description of the alarm condition. If an
interlock failure occurs, power will no longer reach the lamp and
the L
O
button on the Main: System screen as well as on
AMP
N
the CDP will be disabled.
3-22
Figure 3-15 Blocked Files Warning Message
Figure 3-14 Status: Interrogator Menu
Figure 3-16 Alarm Window
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)