Christie CP2000-ZX User Manual page 151

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

System Status (SST)
DESCRIPTION - Retrieve the various system status groups.
SUBCODE
DESCRIPTION OF USE
ALRM
Returns a summary of any active alarms
CONF
Returns configuration data - model, sn, build date, etc
COOL
Returns cooling data - cooling fans, air flow, etc
HLTH
Returns system health
INTE
Returns interlock data
LAMP
Returns LAMP operational data.
None
Returns information on all status groups, with one message per item.
PERI
Returns peripherals data - Cine-IPM, etc
SIGN
Returns signal data - freq, etc.
SYST
Returns system data - power, hours of use, shutter open, etc
TEMP
Returns temperature data
VERS
Returns version numbers
EXAMPLES:
(SST+ALRM?) returns (SST+ALRM!000 002 "101" "Prism temperature")
where parameters are P1=index number, P2=error level, P3=value, P4=description.
Error level is 0=no errors or warnings, 1=warning, 2=error, 3=error and warning
Stop DLP Communication (STP)
DESCRIPTION - Stop communications to DLP Cinema Electronics temporarily, i.e. for DLP software upgrading.
SUBCODE
DESCRIPTION OF USE
NONE
0 - restart DLP communications; 1 - stop DLP communications.
EXAMPLES:
(STP 0) Restart DLP communication
(STP 1) Stop DLP communication
(STP?) Request current state. Example response if (STP!000)
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
Appendix A: Serial API
A-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents