Christie CP2000-ZX User Manual page 139

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

Lamp ID (LID)
DESCRIPTION - Set or Get lamp type (ID) for the currently installed lamp. Supports read back of the list of supported lamp
types.
SUBCODE
DESCRIPTION OF USE
NONE
Set Lamp ID for current lamp. This is read-only control. Lamp ID can be changed with LPC (lamp
change) command only.
EXAMPLES:
(LID?L) List supported lamp IDs
(LID?) Get the lamp id for installed lamp
LampLOC™ Module (LLM)
DESCRIPTION - Allows adjustment of lamp position to optimize intensity and uniformity of the optical system. This is
referred to as the LampLOC™ feature and can be done automatically or manually.
SUBCODE
DESCRIPTION OF USE
AUTO
Set to 1 to do LampLOC™ automatically. It will do calibration first, then moving x, y, z-motor to find the
maximum brightness. Set to 0 to cancel auto adjustment, it will restore the previous position. Reset to 0
when it has finished.
CALI
Set to 1 calibrate all 3 motors, i.e. move all 3 motor to default position. Reset to 0 when it has finished.
MTRX
Moving X-axis motor manually. Data range from - 500 to 500.
MTRY
Moving Y-axis motor manually. Data range from - 500 to 500.
MTRZ
Moving Z-axis motor manually. Data range from - 500 to 500.
NONE
Not Available
STAT
Provides feedback (status) on the progress of the Auto mode. Read-only command. Data range from 0 to
100, where 100 indicates the LampLOC™ is finished.
EXAMPLES:
(LLM+MTRX 100) Move motor-X to position 100
(LLM+AUTO 1) Do LampLOC™ automatically
(LLM+AUTO 0) Abort LampLOC™, it will restore the motors to previous position automatically
(LLM+AUTO?) Get running status. (LLM+AUTO!000) indicates finished, (LLM+AUTO!001) indicates running
(LLM+CALI 1) Motor calibration
(LLM+CALI ?) Returns 1 if calibration is running and 0 if calibration is finished
(LLM+CALI 0) Do nothing. Can not cancel calibration
Adjust All Lens Position Parameters Simultaneously (LMV)
DESCRIPTION - Adjust all lens position parameters simultaneously.
SUBCODE
DESCRIPTION OF USE
NONE
(LMV <lho><lvo><zom><fcs>)
where <lho>, <lvo>, <zom>, and <fcs> represent the horizontal, vertical, focus, and zoom position infor-
mation.
EXAMPLES:
(LMV 1000 1500 500 -500)
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
Appendix A: Serial API
A-11

Hide quick links:

Advertisement

Table of Contents
loading