Replacing The Filter; Replacing The Lens - Christie CP2000-ZX User Manual

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

STEP 8: Close Lamp Door
STEP 9: Turn Wall Circuit ON
STEP 10: Web UI Adjustments
In the Advanced: Lamp History menu of the web user interface, select New Lamp and record lamp type,
serial number and number of the hours logged on to the lamp. If the lamp has not been previously used,
enter 0.
STEP 11: Turn Lamp ON
Press LAMP ON on the CDP.
STEP 12: Adjust LampLOC™
Immediately adjust lamp position (LampLOC™) via the CDP Lamp menu or the Advanced: Lamp
menu in the web interface (refer to
achieve optimized light output by centering the lamp with the reflector and obtaining correct distancing
from the center of the illumination system.
4.5

Replacing the Filter

projector without the filter installed.
Replace the air filter whenever the lamp module is replaced or sooner if operating the projector in a dusty or
dirty environment. Check monthly in all cases. The filter is located on the inputs side of the projector behind
the air filter cover. To replace:
1. Release two tabs on the air filter cover and remove.
2. Slide the air filter out and discard. Insert the new air filter with the airflow indicator facing toward the
projector. NOTE: Never reuse an old air filter. The air filters in this product cannot be cleaned thoroughly
enough for reuse and can lead to the contamination of optical components.
3. Replace the air filter cover by inserting the two bottom tabs into place and then snapping the door closed.
4.6

Replacing the Lens

A variety of primary lenses can accommodate different throw distances and specific types of installations.
Refer to
Section 6 Specifications.
1. Release the lens locking lever (UP position).
2. Pull out the lens and replace it with a different high-brightness or high-contrast lens. NOTE: Always
install the lens with "UP" label in the top position. This will assist in achieving consistent boresight
alignment each time the lens is replaced. Refer to
3. Secure the lens with the lens locking lever (DOWN position).
4. Calibrate the lens. Refer to
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
Section 3.4.7 Advanced
Use only special, high efficiency Christie approved filters. Never operate the
Always discard used air filters.
Turn the lens clamp to the OPEN/UP position.
2.7 Basic Image Alignment
Menu). By adjusting lamp position, you can
Section STEP 6 - Install Lens(es), on page
for details.
Section 4: Maintenance
2-6.
4-11