Section 3: Operation

3.10 Lamp Menu

3.10.1Lamp Mode

Select between one of the three different lamp modes:
• Maximum Brightness mode sets the lamp to run at its
highest power level.
• Constant Intensity mode maintains a specific brightness
level over time. The brightness level can be adjusted via
the Intensity control (see below). As the lamp ages, the
projector will increase power to maintain the desired
brightness. This option is disabled if LiteLOC calibration
has not been performed.
• Constant Power mode maintains a specific power level
for the lamp. The power level can be adjusted via the
Power controls (see below).

3.10.2Power

The Power control represents the amount of power sent to the lamp(s) in Watts. Lower power levels reduce
brightness and extend lamp life. This control is only enabled while in Constant Power mode.
NOTE: This slide bar does not update in real-time when operating in Maximum Brightness or Constant
Intensity mode. To see the amount of power being applied to the lamp while in Maximum Brightness or
Constant Intensity, see the Lamp Info page on the Status tab of the WebUI.

3.10.3Intensity

The intensity control represents the target brightness for the LiteLOC system. The value is a percentage of the
maximum brightness of the lamp(s). This control is only enabled while in Constant Intensity mode.
3.10.4Warn When Lamp Reaches (Hours)
This control causes the projector to present a warning message when the lamp has a recorded ON time that
exceeds the specified number of hours. The warning will be displayed via the status page for each lamp, where
applicable. A value of 0 will diable this feature.
NOTE: This setting is user-defined only. It has no bearing on lamp warranty and is not tied to actual lamp life
in any way.

3.10.5Lamp S/N

This option allows the serial number for the current lamp to be changed. This will apply the serial number to
the current lamp statistics file. It will not archive the current statistics as done by the Change Lamp function.
3-50