Advertisement

Blue Formatter Config version
Blue Formatter Gamma version
Blue Formatter BitSequence version
Blue Formatter Gamma version
Temperatures (degrees Celsius)
Prism temperature
Red DMD temperature
Green DMD temperature
Blue DMD temperature
Integrator temperature
Ambient air temperature
Exhaust air temperature
Motherboard temperature
PCM temperature
I2C Bus A temperature
I2C Bus C temperature
I2C Bus D temperature
I2C Bus E temperature
Cooling
Main Inlet 1 fan
Main Inlet 2 fan
Main Inlet 3 fan
Card cage fan
Laminar air device (LAD)
Liquid pump
Peripherals
Auxiliary Lens Installed Status
ILS Install Status
ILS Online Status
ILS Power Status
ILS Temperature
ILS X Sensor Status
ILS Y Sensor Status
ILSILS Focus Sensor Status
ILS Zoom Sensor Status
ILS Board ID
ILS Boot Version
ILS Software Version
ILS Hardware Version
Health
292-A Total SMPTE error count
292-A Recent SMPTE error count
292-B Total SMPTE error count
292-B Recent SMPTE error count
DDR memory test
Flash memory test
EDID checksum test
FPGA checksum test
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
60 °C = warning,
70 °C = critical
63 °C = warning,
68 °C = critical
63 °C = warning,
68 °C = critical
63 °C = warning,
68 °C = critical
90 °C = warning,
100 °C = critical
40 °C = warning,
45 °C = critical
65 °C = warning,
75 °C = critical
RPMs of internal fan #1. Failure triggers an alarm window.
RPMS of internal fan #2. "0RPM" = device failure, "FAIL" = sensor failure
RPMs of internal fan #3. "0RPM" = device failure, "FAIL" = sensor failure
RPMs of electronics card cage fans
RPMs of laminar airflow device for DMDs
RPMs of liquid cooling pump
Section 3: Operation
3-19