Christie CP2000-ZX User Manual page 22

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

Section 2: Installation & Setup
STEP 8 - Connect to Power
CP2000-ZX is designed as a permanently wired connection or pluggable type B connection (P/N 116-102104-
01). Connecting the projector to your AC supply can vary according to the country or state in which the
projector is installed. For any installation, always follow the electrical code for your location.
for safety. Never compromise safety by returning the current through the ground. 3) Connect
ground FIRST to reduce shock hazard from high leakage. 4) Protection from overcurrents,
short circuits and earth faults must be part of the building installation. The disconnect device
(double pole switch or circuit breaker with minimum 3mm contact gap) must be readily acces-
sible within the projection room. 5) Do not use a wall breaker greater than 32SA.
the cable from rubbing against the projector knockout plate and becoming damaged.
To install a permanent connection, refer to
To install a Pluggable type B connection using a Nema-L630A 250V Power Plug, refer to
Pluggable Type B
Installing a Permanent Connection
Follow these guidelines:
A 30-32A double pole, UL listed wall circuit breaker is required. It must be part of the building
installation and easily accessible.
Use 10AWG or 8AWG wiring: The distance between the wall circuit breaker and the projector must
not exceed 20 metres using 10AWG cables or 30 metres using 8AWG cables.
For North American installations, use at least 10AWG copper wires for the connection of the main
AC supply to the projector's ground lug.
Copper or aluminum are acceptable as conductor wiring material to the terminal block.
1. A small electrical access plate is located in the lower right corner of the projector faceplate. Loosen the two
screws and slide the plate forward to expose the terminal block underneath. See Figure 2-10.
2-8
1) Certified electrician required. 2) Ground (earth) connection is necessary
Use an appropriate strain relief connector on the AC supply cable to prevent
Connection.below.
Figure 2-10 Remove Access and Knockout Plates
Installing a Permanent Connection
below.
Installing a
CP2000-ZX User Manual