Lamp Menu

The Lamp menu provides controls for optimizing lamp alignment
(LampLOC™), maintaining a consistent light output over time (LiteLOC™),
or setting a precise power level for the lamp. Two read-only areas display
related lamp performance details - the side bar graph represent the current
light output and, if LiteLOC™ is enabled, a heavy line shows the chosen
LiteLOC™ setting.
Perform Lamp Change using the CDP
1. From the Lamp > Lamp Change menu, select Lamp S/N.
2. Enter the lamp serial number.
3. From the Lamp > Lamp Change menu, select Hours Used.
4. Enter the lamp hours on the bulb.
5. Select "Press Enter to Change Lamp" to accept the lamp info entered in the steps above. NOTE: If
"Press Enter to Change Lamp" is not selected before leaving the Lamp Change menu, changes will not
take effect.
Refer to
Section 3.6 Working with the Lamp
similar controls accessible via the web user interface.

Lens Control Menu

the MALM to the OUT position before performing any lens calibrate or reset functions on the
Motorized Primary Lens Mount to prevent collision between the projection lens and the
MALM. 2) Hazardous moving parts. Keep fingers and other body parts away.
The Lens Control menu enables users to adjust focus, Horizontal (X) and Vertical (Y) offsets, and zoom of the
lens. It also provides the option to reset and calibrate the lens, enable the intelligent lens system (ILS) and
perform adjustments in MANUAL mode. Refer to Channel: Lens Menu, on page 3-30 for a general
description of the same controls accessible from the web user interface. NOTES: 1) Using the knobs on the
lens mount to adjust these positions does not save the settings to the channel. They are designed for temporary
use and will therefore be lost once the channel changes. 2) Only Advanced users can modify channel settings.
3) Keep clear of rotating parts. Remotely operated motors may start to spin without warning. 4) Avoid long
hair, jewelry, and loose clothing exposure to the knobs during manual adjustment. 5) In case of emergency,
unplug the line cord to immediately halt movement of the lens mount.
Lens Adjustment
This menu enables users to adjust the Horizontal (X) and Vertical (Y) offsets
of the lens motors, as well as adjust focus and zoom. To view the changes,
ensure a test pattern is displayed. Once the adjustments are adequate for the
particular application, the settings can be saved to the specific channel. To
adjust Focus and Zoom use the right/left arrow buttons to adjust the min./max
values. The Horizontal (X) and Vertical (Y) values are fixed to ±2050 to
ensure the motor offsets are not overridden.
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
1) If the Motorized Auxiliary Lens Mount (MALM) is present, ensure to move
as well as
Section 3.4.7 Advanced Menu
Section 3: Operation
Lamp
==============
=========
Figure 3-4 CDP Lamp Menu
Options
for a description of
Lens Control
======
=====
Figure 3-5 CDP Lens Control
Menu Options