Section 3: Operation

3.10.4 If the Lamp Will Not Turn On

If the lamp fails to ignite, the projector will automatically re-try ignition using 100% of the maximum power
acceptable for the lamp. If this re-try also fails, and there is no error code indicating a specific problem such as
an open lamp door or an over-temperature condition, the lamp size may be incorrectly defined. For instance,
the defined "Lamp Size" may be 2 kW when a 6 kW lamp is present. To check the "Lamp Size" setting, press
M
ENU
while the lamp is off. The
2000, 3000, 4500 or 6000 watts, depending on its most recent setting (factory default=6000). Enter the
password (unless it has been turned off) and select the lamp that is currently installed. If the lamp still does not
ignite, a Christie accredited service technician should check all lamp connections and, if OK, replace the lamp.
Refer to
Section 5

3.10.5 Lamp Menu

Whenever you install a new lamp in the projector, access the
Lamp
menu to record the lamp serial number in the projector's
memory. You can also choose a lamp mode for regulating power
and Lamp Message check box.
LAMP S/N
(read only) option is the serial number recorded for the
current lamp. When you install a new lamp and enter its serial
number, the number appears here.
Select the
LAMP MESSAGE
message that appears upon power-up when the lamp has reached
the specified lamp limit and should be replaced. Clear the check
mark to prevent display of this message. When your lamp expires,
only the status display on the back of the projector provides the
visual warning to replace the lamp. In addition, the LED's next to
the built-in keypad flash "LP" when the lamp time has expired.
NOTES: 1)
It is recommended that the Lamp Message check box remain enabled.
appears, press E
power-up until you install a new lamp.
Set the
LAMP LIMIT
triggers a lamp message on-screen (if enabled). Recommended limits for each of the four lamp sizes are listed
in
Table 3.7
later in this section.
NOTES: 1)
If you change modes over the life of a lamp, the lamp limit you originally expected may no longer be
possible.
recommended that Lamp Limit not exceed the warranted lamp life, otherwise a lamp could become
dangerously fragile with overuse.
Set which
LAMP MODE
choose to run the lamp as bright as possible (i.e., always using maximum power-this
is the default upon power up), or you can power the lamp with a specific wattage
appropriate for the installed lamp, or you can set a specific intensity (brightness) to
maintain. Although there are exceptions, generally higher light output or higher power settings can shorten
lamp life.
Use the lamp mode that best suits your brightness needs. For example, in a tiled application, you may want to
precisely match brightness levels between adjacent images. If you always want your images to be as bright as
possible, choose Max Brightness.
3-60
LCD STATUS DISPLAY
Troubleshooting.
check box to enable a warning
XIT
to temporarily cancel the message. The message will continue to appear each time you
to the number of hours you expect to log on the current lamp before replacing it. This
2)
Turning the lamp on and off reduces lamp life significantly, as do other factors.
you want to use in order to control the light output. You can
at the rear of the projector shows a "Lamp Size" of
2)
When a lamp warning message
3)
It is