2.13.5 Admin: Lamp Menu

From the Admin: Lamp menu, installers can record minimum and maximum footlambert (fL)
readings to define a range from which other lamp readings are interrpolated.
A
Min Power: Enable to automatically
reduce lamp power to its minimum
B
Foot Lamberts Calibration: Record light
measured from both extremes of power -
measured at screen projector will be able
to interpolate future light output in foot
lamberts
C
Max Power: Enable to automatically
increase lamp power to its maximum
To set FootLamberts Calibration
1. Ensure the lamp is turned ON.
2. Press Min Power to set the lamp power to it's lowest value for the installed lamp. NOTE: If
enabled, LiteLOC™ is disabled when Min Power is pressed to allow setting minimum power for
the lamp. Once the value is applied, LiteLOC™ is enabled to its original state again.
3. Enter the FootLamberts measured for the min lamp power in the Min FL text box by typing the
value or using the up/down arrow buttons.
4. Press Apply to save the Min FL value. Once Apply is pressed, the Min Power button becomes
unchecked and the Apply button becomes grayed-out. Lamp power returns to the lamp power it
was before Min Power was activated.
5. Press Max Power to set the lamp power to it's highest value for the installed lamp. NOTE: If
enabled, LiteLOC™ is disabled when Max Power is pressed to allow setting maximum power for
the lamp. Once the value is applied, LiteLOC™ is enabled to its original state again.
6. Enter the FootLamberts measured for the max lamp power in the Max FL text box by typing the
value or using the up/down arrow buttons.
7. Press Apply to save the Max FL value. Once Apply is pressed, the Max Power button becomes
unchecked and the Apply button becomes grayed-out. Lamp power returns to the lamp power it
was before Max Power was activated.
CP2000-M/MR Setup Guide
020-100205-03 Rev. 1 (05/09)