Appendix A: Serial API
Local Settings (LOC)
DESCRIPTION - Set the localization options such as Language and display options for temperature units.
SUBCODE
DESCRIPTION OF USE
LANG
Set the primary language. 0 - English. (Choices are Deferred past V1.0)
TEMP
Set the temperature units. 0 - Celsius. (Choices are Deferred past V1.0)
TIME
Set Time format. 0 - 24 hour, 1 - 12 hour.
EXAMPLES:
(LOC+TIME 1) Set time zone to standard 12 hour
(LOC+TIME?1) Get list of formats
(LOC+TIME?)(LOC+TIME!001) Get time format
None
Lamp Changed (LPC)
DESCRIPTION - Record current lamp information into the lamp history, then start a new entry. Set lamp information of a new
lamp type ID, serial number, and pre-used hours.
SUBCODE
DESCRIPTION OF USE
LPID
Set lamp type ID for the new lamp
PREV
Set lamp previous lamp hours for the new lamp
SERL
Set lamp serial number for the new lamp
EXAMPLES:
(LPC+LPID "CDX-30") Set lamp type ID
(LPC+SERL "CDX30-001") Set lamp serial number
(LPC 1) Save information to lamp history
(LPC 1) Consecutive lamp changes requires 5 - 10 second time difference as writing to EEPROM is involved.
Lamp Hours (LPH)
DESCRIPTION - Read only control, get information on installed lamp.
SUBCODE
DESCRIPTION OF USE
FLSK
Return Total failed lamp strikes on the installed lamp
FRSK
Return Total failed lamp restrikes on the installed lamp
LPOF
Return Total lamp unexpected off times on the installed lamp
NONE
Return Lamp usage for current lamp in hours.
TLSK
Return Total lamp strikes on the installed lamp
EXAMPLES:
(LPH?) Get usage in hours
(LPH+FLSK?) Get lamp strikes