Advanced Menu; Advanced: Preferences Menu - Christie CP2000-ZX User Manual

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

Section 3: Operation

3.4.7 Advanced Menu

The Advanced menu consists of six menus that enable advanced operators, administrators and installers to
define numerous operating parameters, work with lamp settings, ad a new lens, load and/or display test
patterns, set up users and define their access rights.

Advanced: Preferences Menu

The Advanced: Preferences menu provides access to various system parameters, as shown in Figure 3-25.
This is further described in Summary Advanced: Preferences Menu Options below.
Enter # hours you expect to
log on the lamp before
expiry.
Enable to display a message
when lamp expires (reaches
lamp limit).
Enable to display message
when lamp over heats.
Enable to display message
when fan fails.
Enable to display a "Lamp
Rotation Required" mes-
sage when lamp reaches
50% of its expired life.
Sets the time delay for the
toggle buttons in millisec-
onds.
Table 3.13 Summary of the Advanced: Preferences Menu Options
ADVANCED: PREFERENCES MENU OPTIONS
Lamp Expiry
Expiry Message
Alarm Triggers
Toggle Delay
Language
Data Logging
Temperature Dis-
play Mode
Date
Time
3-32
Choose the level of data
logging for the projector.
Figure 3-25 Advanced: Preferences Menu Options
Enter the number of hours (0 - xxxx) that are expected to be logged on the current lamp.
When checked, an alert window displays when the lamp expiry is reached.
Choose the conditions you want to trigger an Alarm Window (in addition to interlocks, communica-
tion faults, DMD over-temperature and lamp failures which are all permanent triggers). It is strongly
recommended all triggers remain enabled during normal operation. Disable only in rare emergencies
when the alarm appears to be malfunctioning without real errors.
Sets the time delay for the toggle buttons. Time is recorded in milliseconds.
Choose a default language for all web UI screens. The login window will also display in this lan-
guage, but can be modified at any time.
Choose the level of data logging for the projector. Options include Minimal, Normal, and Debug.
Select whether to display temperature in Celsius or Fahrenheit.
Reset date as desired. Click the calendar icon to display a calendar from which you can select a date.
Click the clock icon to reset the displayed time. Choose from 24-hour or standard 12-hour formats.
Time is always displayed on each window in the chosen format. Time Zone - Choose the time-zone.
Enable calendar from
which a date can be cho-
sen.
Select time. Click Set to
save adjustment.
Enable to display time in
a 24-hour format, dis-
able for 12-hour stan-
dard format.
Choose a time zone.
Enable to display vari-
ous temperature vari-
ables in °C.
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)