Appendix A: Serial API
Remote Access Level (RAL)
DESCRIPTION - Set the remote serial protocol access level for a serial communications port. NOTE: Valid sections are 0 -
No Access, 1 - Login Required, 2 - Free Access
SUBCODE
DESCRIPTION OF USE
None
Set the access level on Ethernet all ports.
PRTA
Set the access level on RS232 port A.
EXAMPLES:
(RAL 0) Disable remote serial protocol access for all Ethernet ports
(RAL?) Get access level for Ethernet ports (RAL!0)
(RAL+PRTA 2) Set remote serial protocol access level on port A to free access
(RAL+PRTA?) Get access level (RAL+PRTA!2)
SCCI Settings (SCC)
DESCRIPTION - Enable/disable the SCCI control.
EXAMPLES:
(SCC1) Enables the SCCI control
Screen Format (SCF)
DESCRIPTION - Select Screen format file which describes the geometry for the output image.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid Range is 101 - 164.
NONE
Select screen file for the current channel.
RFSH
Set (1) to refresh files, 0 do nothing.
TEMP
Select the screen file as DLP active file, do not change channel settings.
EXAMPLES:
(SCF+C108 "FLAT") Use file "FLAT" on channel 108
(SCF+C108?) Get screen file name on channel 108
(SCF?L) List all available entries of screen control
(SCF+TEMP "FLAT") Use file "FLAT" as DLP active file
(SCF+RFSH 1) Refresh TI file list
SMPTE Field Bit (SFB)
DESCRIPTION - Set SMPTE Field Bit
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid Range is 101 - 164.
NONE
Set SMPTE Field Bit for the current channel.
EXAMPLES:
(SFB?L) List all entries on SMPTE Field Bit control
(SFB+C101 1) Set SMPTE Field Bit to 1 on channel 101
(SFB+C101?) Get SMPTE Field Bit on channel 101
A-20
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)

Hide quick links: