Backup (BAK)
DESCRIPTION - This control backs up various parts of the system. Files are zipped, date/time stamped and placed in the /var/
www/backup directory.
SUBCODE
DESCRIPTION OF USE
CFIL
Retrieve the name of the last sucessful configuration backup. Read only sub code.
CHAN
Meaningless value. Simply used to trigger. Use 1.
CONF
Meaningless value. Simply used to trigger. Use 1.
HFIL
Retrieve the name of the last sucessful channel file
IFIL
Retrieve the name of the last sucessful interrogator file
INTR
A value of 0 will launch the interrogator in normal mode. This collects the common logs in the system. A
value of 1 will launch the interrogator in enhanced mode. Enhanced mode offers additional debug info as
well as provides the normal info.
ISTA
Retrieve the current state of the interrogator. 0 means not running.
PFIL
Retrieve the name of the last sucessful preference backup. Read only sub code.
PREF
Meaningless value. Simply used to trigger. Use 1.
UFIL
Retrieve the name of the last sucessful user backup. Read only sub code.
USER
Meaningless value. Simply used to trigger. Use 1.
EXAMPLES:
(BAK+CONF 1) Backup all configuration controls
(BAK+USER 1) Backup all users
(BAK+INTR 1) Run interrogator enhanced
(BAK+INTR 0) Run interrogator normal
(BAK+CFIL?)(BAK+CFIL!"http:192.168.0.0/backup/config_model_sub_serial_date_time.tar")
(BAK+CHAN 1) - Backup all channel controls
Baud Rate (BDR)
DESCRIPTION - Set the baud rate for a serial communications port.
SUBCODE
DESCRIPTION OF USE
PRTA
Set the baud rate on port A. Rates can be 1200, 2400,9600.19200,38400,57600 or 115200
EXAMPLES:
(BDR+PRTA "115200") Set baud rate on port A to 115200 bits per second
(BDR+PRTA?) Get baud rate (BRD+PRTA! "115200")
Emergency Stop (BGT)
DESCRIPTION - Emergency Stop for commands that are running in a separate thread.
SUBCODE
DESCRIPTION OF USE
STOP
Action command (no argument required)
EXAMPLES:
(BGT+STOP) Stop any currently running control threads
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
Appendix A: Serial API