Status Menu And Alarm Conditions; Test Patterns Menu - Christie CP2000-ZX User Manual

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

Status Menu and Alarm Conditions

There are three status LEDs on the CDP for the purpose of indicating projector
status. Table 3.3 details the various conditions of the LEDs and their meaning. In
addition to the visual indicator of the LEDs, you can check the status of specific
projector components through the CDP Status menu. Refer to
Menu
and
Section 3.4.5 Alarm Window
web user interface.
Table 3.3 Status LEDs: Indicating Projector Status
ON
(GREEN)
Solid Green
Flashing Green
Flashing Green
OFF
Solid Green
Solid Green
Flashing Green
On or Off
On or Off
If the projector encounters a system error or malfunction, the red ERROR LED will begin flashing. At this
point, press ENTER to display the alarm message on the CDP display. This acknowledges that you have seen
the message and the ERROR LED will turn a solid red. The ERROR LED will remain in this state until the
problem is resolved or a new error is encountered by the projector. If a safety interlock, content security lock or
DMD over-temperature fault occurs during operation, the ERROR LED will illuminate in the same way,
however power to the lamp will automatically be turned OFF and the lamp button will remain disabled until
the problem is fixed. NOTE: Refer to
information on projector status and alarm conditions using the web user interface.

Test Patterns Menu

The Test Patterns menu enables users to disable the test pattern feature or select from a list of test patterns used
for troubleshooting and setup purposes.
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
for similar controls available through the
READY
ERROR
(YELLOW)
(RED)
Solid Yellow
Solid Red
Flashing Yellow
Flashing
Red
Solid Yellow
OFF
Solid Yellow
OFF
Solid Yellow
OFF
OFF
OFF
Flashing Yellow
OFF
On or Off
Flashing
Red
On or Off
Solid Red
Section 3.4.4 Status Menu
Section 3.4.4 Status
DESCRIPTION
Initial Power ON.
Flashes 3 times. Press and hold.
Power OFF button to stay in Failsafe Mode.
Warm Up (to Standby Mode)
Standby Mode.
Power is OFF.
Lamp is OFF.
Power is ON.
Lamp is OFF.
Power is ON.
Lamp is ON.
Cool Down (to Power On or Standby Mode).
New alarm condition detected (such as criti-
cal warning detected by DMD temperature
sensors).
Alarm condition exists, but has been
acknowledged in the web user interface or
CDP.
and
Section 3: Operation
==========
Alarms
Temperatures
Fan Speeds
Interlocks
Security
Lamp Status
Config Status
System Status
System Health
Versions
Serials
Signal
Peripheral
Figure 3-7 CDP Status
Menu Options
Section 3.4.5 Alarm Window
Status
=======
for more
3-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents