STEP 7 - Install First Lamp
handled. Always wear approved protective safety clothing whenever lamp door is open or
while handling the lamp.
1. Open lamp door
Using the security key provided, open the lamp door and inspect the empty lamp cooling compartment.
Caution! Do not place heavy objects on the open lamp door.
2. Position anode yoke assembly according to lamp type
Check the position of the anode yoke assembly for the lamp type that will be used in the projector. Table
2.1 lists all available lamp types for the CP2000-ZX and the position of the anode yoke assembly.
Table 2.1 Lamp Types Available for CP2000-ZX and Anode Yoke Position
LAMP
2.0 kW
CDXL-20
3.0 kW
CDXL-30
3.0 kW
CDXL-30SD (short arc)
3. Install the lamp. Refer to
warnings, and wear protective clothing and shielding.
Important! The projector is shipped with a lamp extension nut fastened to the cathode end of the lamp
holder. Use this nut with CDXL-30SD lamps only. This will ensure proper placement of this lamp type. If you
are installing any other lamp type, remove this nut and retain it for future lamp replacements. Leaving the
extension nut on with the wrong lamp type can lead to extremely dim light output.
CP2000-ZX User Manual
020-100006-05 Rev. 1 (05-2009)
Qualified technical required! High-pressure lamp may explode if improperly
TYPE
Move the lamp cradle as far forward as possible (position closest to igniter)
Move the lamp cradle to the rear position, which is approximately 1" closer to
the reflector.
Section 4.4 Replacing the Lamp
Figure 2-9 Anode Yoke Location
Section 2: Installation & Setup
ANODE YOKE POSITION
for lamp replacement instructions. Observe all