Control Data Corporation CYBER 170 Series Operator's Manual page 80

Nos version 1
Table of Contents

Advertisement

Entry
1.0NSW3.
1.0NSW4.
1.0NSW5.
1.0NSW6.
TELEX.
Response
Abort the time-sharing subsystem
on all abnormal conditions.
This
ensures that the subsystem does
not continue
to operate if an
internal malfunction occurs. This
may be used with sense switch 5
to enable an analyst to determine
the
problem.
Some
conditions
cause the time-sharing subsystem
to abort even though sense switch
3 is not set.
Enable
dump
on
normal
termination.
This
option should
be activated whenever a dump is
desired after a 1. STOP. entry.
Call
DMP,
which
dumps
information to the OUTPUT file
after the time-sharing subsystem
is dropped or aborted. This option
provides a listing which may assist
an
analyst
in
determining
the
problem
that
existed when the
subsystem
dropped
or
aborted.
This sense switch is set by default
when the time-sharing subsystem
is activated.
Release OUTPUT file containing
dump
information
written after
the
time-sharing
subsystem
is
dropped
or
aborted
(refer
to
1. ONSW5. operation) immediately
after the dump is taken.
When
sense switch 6 is not set, the
OUTPUT file is not released until
the
time-sharing
subsystem
is
terminated.
It
is
then printed
with the dayfile.
This
switch
applies
only
when
sense switch 5 is set.
Calls the time-sharing subsystem to control point
1. This command is not valid if a job currently
assigned to control point 1 has a queue priority
greater than MXPS.
The time-sharing executive
must be active before user can enter jobs from a
time-sharing terminal. Use the T display (refer to
section 4) to monitor activity at the time-sharing
subsystem control point.
Several options are available to control
the
operation of TELEX.
Select these options by
setting sense switches after the subsystem is
activated.
Although normal operation does not
require these sense switches to be set, sense
switch 5 (1.0NSW5.) is set by default when the
time-sharing subsystem is activated.
Once set,
the sense switch may be turned off again by
entering
1.0FFSWx.
(x
is
the
sense switch
number.)
Entry
1.0NSW1.
1.0NSW2.
1.0NSW3.
1.0NSW4.
1.0NSW5.
1.0NSW6.
TAFffff.t
Response
When
the
time-sharing
sub-
system is terminated (by 1.STOP
command),
enter
users
into
recover
state
and
inhibit
restarting operations.
Enable
the
time-sharing
sub-
system to use the delay queue
feature.
This
allows
resp6nse
time to appear more consistent to
users by delaying response in a
lightly loaded system.
Analysts
can set this parameter by altering
assembly constants within TELEX.
Abort the time-sharing subsystem
on all abnormal conditions.
This
ensures that the subsystem does
not continue
to operate if an
internal malfunction occurs. This
may be used with sense switch 5
to enable an analyst to determine
the
problem.
Some
conditions
cause the time-sharing subsystem
to abort even though sense switch
3 is not set.
Enable dump on normal termi-
nation.
This
option
should
be
activated
whenever
a
dump
is
desired after a 1.STOP entry.
Call
DMP,
which dumps infor-
mation to the OUTPUT file after
the
time-sharing
subsystem
is
dropped or aborted.
This option
provides a listing which may assist
an
analyst
in
determining
the
problem
that existed when the
subsystem
dropped
or
aborted.
This sense switch is set by default
when the time-sharing subsystem
is activated.
Release OUTPUT file containing
dump
information
written after
the
time-sharing
subsystem
is
dropped
or
aborted
(refer
to
1.0NSW5.
option)
immediately
after the dump is taken.
When
sense switch 6 is not set, the
OUTPUT file is not released until
the
time-sharing
subsystem
is
terminated.
It
is
then
printed
with the dayfile.
This
swtich
applies
only
when
sense swi tch 5 is set.
Calls the transaction subsystem to control point
2.
This command is not. valid if a job currently
assigned to control point 2 has a queue priority
greater than MXPS.
The transaction subsystem
must be active for transaction processing to take
place.
t
The characters ffff are optional; if required, installation personnel must supply the one to four alphanumeric characters
to be used.
I
3-20
60435600 L

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CYBER 170 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel