MESSAGE
DETECTED IN RPL.
DEVICE DOES NOT EXIST.
REPLY GO TO RETRY - DROP TO OFF DEVICE.
DEVICE NOT FIRST IN CHAIN.
DEVICE NOT FIRST IN CHAIN.
DEVICE NOT READY.
REPLY GO TO RETRY - DROP TO OFF DEVICE.
DEVICE NOT REMOVABLE.
\ J
\ J
SIGNIFICANCE
Error was encountered during the building of
the system library.
Central memory resident
overlay (OVL) or absolute (ABS) program is
not formatted correctly.
Deadstart
processing halts when this error is
detected.
K-display message indicating that the
cartridge storage unit or the mass storage
transport (as indicated in line 1 of
message) is not configured as described in
the EST entry.
The device specified to be reconfigured was
not the first equipment in a linked device.
To retain the integrity of a linked device
configuration, this is not allowed.
To prevent destroying the integrity of a
chained multispindle device, initialization
will take place only if the device is first
in the chain.
K-display message indicating that the
cartridge storage unit or mass storage
transport (as indicated in line 1 of
message) returned a NOT READY response.
A nonremovable device was selected for
chaining in a multispindle string.
Before
initialization and chaining can be
performed, it is required that all physical
units to be included in the multispindle
string be defined as removable.
ACTION
the site analyst.
Redeadstart at a
different tape density
or use another tape
unit or a different
deadstart tape. If the
error persists, inform
the site analyst.
Inform 'the site analyst
and/or.customer
engineer.
If the
equipment can be
attached, enter K.m.GO.
Otherwise enter
K.m.DROP.
m Message ordinal
Enter the CLEAR or
RERUN command and
redefine the first
equipment in the linked
device.
The only input accepted
at this time is RERUN or
CLEAR.
Enter RERUN to
update list (on K
display) of devices with
initialize status set.
If first device in chain
is not included in new
list, enter CLEAR to
clear initialize status
for the current device.
Either make the device
ready and enter K.m.GO
or enter K.m.DROP to
logically turn off the
device.
m Message ordinal
Enter CLEAR to clear
initialize status for
nonremovable device.
'.
"'--~'
\.
ROUTINE