Control Data Corporation CYBER 170 Series Operator's Manual page 202

Nos version 1
Table of Contents

Advertisement

-
~
00
CJ)
Q
"' "
W
CJ1
CJ)
Q
Q
t"'
MESSAGE
EQxx,CHcc Adddd INCOMPLETE TRANSFER.
EQxx,CHcc CONTROLLER HUNG BUSY.
EQxx,CHcc, CONTROLLER RESERVED.
EQxx,CHcc Emmmm PFC ERROR.
EQxx,CHcc Fffff FUNCTION TIMEOUT.
SIGNIFICANCE
An
incomplete data transfer was detected
by a local batch equipment driver.
EQ
One of the following equipment types.
xx
CP
415 card punch
.
CR 405 card reader
LP
Any line printer
LR
580-12 line printer
LS
580-16 line printer
LT . 580-20 line printer
EST ordinal of local batch
cc
Channel number
equipment
dddd Octal byte count not transferred
The specified local batch controller did
not drop BUSY status.
EQ One of the following equipment types.
CP
415 card punch
CR
405 card reader
LP
Any line printer
LR
580-12 line printer
LS
580-16 line printer
LT
580-20 line printer
xx
EST ordinal of local batch equipment
cc
Channel number
K-display message indicating that
equipment xx could not be accessed
because controller was reserved.
xx
EST ordinal of device
cc
Channel number
Detected PFC error on the specified local
batch equipment.
EQ
One of the following equipment
types.
LR 580-12 line printer
LS
580~16
line printer
LT 580-20 line printer
xx
EST ordinal of local batch equipment
cc
Channel number
mmmm Maintenance status; bits 10 and 9 as
follows.
01
Valid format code was set but is
not in PFC buffer
10
Internal PFC parity error
11
PFC load overflow
No response (inactive) was received after
a function code was issued to the specified
local batch equipment (converter and
equipment status unavailable).
ACTION
Inform customer engineer.
Inform customer engineer.
Refer to section 8
for possible action.
Inform site analyst.
Inform customer engineer.
Inform customer engineer.
ROUTINE
QAP
QAP
MREC
QAP
QAP,
lCD